À½ÉʾðÊó
RocketRAID 3000 ¥·¥ê¡¼¥º
RocketRAID 2000 ¥·¥ê¡¼¥º
PCI-e
RocketRAID 2522
RocketRAID 2340
RocketRAID 2322
RocketRAID 2320
RocketRAID 2314MS
RocketRAID 2314
RocketRAID 2312
RocketRAID 2310
RocketRAID 2304
RocketRAID 2302
RocketRAID 2300
PCI-X
RocketRAID 2240
RocketRAID 2224
RocketRAID 2220
RocketRAID 2210
RocketRAID 1000 ¥·¥ê¡¼¥º
ATA RAID ¥·¥ê¡¼¥º
 
 
 
 
 
À½ÉʾðÊó -> Exnternal RAID HBA -> RocketRAID 2314MS  
[BIOS+Driver][Data Sheet][User manual][Cable Matrix][Enclosure Option ]
[Compatibility List]
Cables Not Include
 
RocketRAID 2314MS Highlights

PCI-Express x4(x8¡¢x16Âбþ)

1¥Ý¡¼¥È³°Éômini-SAS(3Gb/s)¥³¥Í¥¯¥¿ÅëºÜ

ºÇÂç4Âæ¤ÎSATA­¶¤Þ¤¿¤ÏSATA HDD¥µ¥Ý¡¼¥È

Port Multiplier (PM) ready up to 20 Drives
RAID0¡¢1¡¢5 ¡¢10µÚ¤Ó£Ê£Â£Ï£ÄÂбþ

¥µ¥Ý¡¼¥ÈOS¡§Windows (XP, 2000ޤServer 2003ޤx64ޤEditionޤVista)ޤ Linuxޤ FreeBSD µÚ¤Ó Mac OS XÂбþ

RocketRAID 2314MS Host Adapter

RocketRAID 2314MS¤Ï³°ÉôÀܳÍÑmini-SAS¥³¥Í¥¯¥¿¤òÅëºÜ¤·¤Æ¤ª¤ê¡¢¤³¤ì¤òÍøÍѤ¹¤ë¤³¤È¤Ë¤è¤Ã¤Æ¡¢¹â¿®ÍêÀ­¤Ç³î¤Ä¡¢°ÂÁ´¤Ê³°Éô¥³¥Í¥¯¥¿µ»½Ñ¤òÄ󶡤·¤Þ¤¹¡£³°Éômini-SAS¥³¥Í¥¯¥¿¤Ï¹â®¥Ç¡¼¥¿ÅÁÁ÷¤È¹âÂӰ襢¥×¥ê¥±¡¼¥·¥ç¥ó¤Î¤¿¤á¤Ë¡¢ºÇÂç2¥á¡¼¥¿¡¼¤ÎŤµ¤Ë㤹¤ë¤³¤È¤¬¤Ç¤­¤Þ¤¹¡£³°Éômini-SASÀܳ¤È¥±¡¼¥Ö¥ë¤ËÃÖ¤­´¹¤¨¡¢À߷פ¹¤ë»ö¤Ç¡¢¾®¡¦Ã浬ÌϤδë¶È¥µ¡¼¥Ð¤äSOHO¸þ¤±¥µ¡¼¥Ð¤ËɬÍפǤ¢¤ë¹â®¥Ç¡¼¥¿ÄÌ¿®¤ÎÄ󶡤ò¼Â¸½¤·¤Þ¤¹¡£

»ÅÍÍ

PCI-Express x4(x8¡¢x16Âбþ)

1¥Ý¡¼¥È³°Éômini-SAS(3Gb/s)¥³¥Í¥¯¥¿ÅëºÜ

ºÇÂç4Âæ¤ÎSATA­¶¤Þ¤¿¤ÏSATA HDD¥µ¥Ý¡¼¥È

Port Multiplier (PM) ready up to 20 Drives
RAID0¡¢1¡¢5 ¡¢10µÚ¤Ó£Ê£Â£Ï£ÄÂбþ

NativeCommandQueuing(NCQ)Âбþ

Online Capacity Expansion (OCE)¤ÈOnline RAID Level Migration (ORLM)¤òÁõÈ÷

ÅŸ»ÅêÆþ»þ¤ÎHDD¤ÎÅÅÎϾ徺¤òÍÞ¤¨¤ë¡Ö¥¹¥¿¥Ã¥¬¡¼¥É¥É¥é¥¤¥Ö¥¹¥Ô¥ó¥¢¥Ã¥×(Staggered Drive Spin-up)¡×¤ò¥µ¥Ý¡¼¥È

HDD¤Î¾õÂÖ(Activity / Failed)¤òLED¤Ë¤Æ³Îǧ²Äǽ

SES2¥¨¥ó¥¯¥í¡¼¥¸¥ã¡¼¤Ø¤Î¥Þ¥Í¡¼¥¸¥á¥ó¥È¥Õ¥¡¥ó¥¯¥·¥ç¥óÂбþ

RAID¥¢¥ì¥¤¤«¤é¤ÎBIOS Booting (INT13)¤ËÂбþ

¹â®¥Ð¥Ã¥¯¥°¥é¥¦¥ó¥É½é´ü²½¤Ë¤è¤êRAID¤òľ¤Á¤Ë»ÈÍѲÄǽ

¥é¥¤¥È¥¹¥ë¡¼µÚ¤Ó¥é¥¤¥È¥Ð¥Ã¥¯¥­¥ã¥Ã¥·¥åµ¡Ç½¤ËÂбþ
¥Û¥Ã¥È¥¹¥ï¥Ã¥×¤ª¤è¤Ó¥Û¥Ã¥È¥¹¥Ú¥¢¤ò¥µ¥Ý¡¼¥È

Online array roaming¤Ë¤è¤ê¡¢¸Î¾ã»þ¤ÎRAID¥·¥¹¥Æ¥à¤Î¥Ç¡¼¥¿¤äRAID¾ðÊó¤ò¡¢Ê̤ÎRAID¥·¥¹¥Æ¥à¤Ë°Ü¤¹¤³¤È¤¬²Äǽ

¸Î¾ã¤·¤¿RAID¥¢¥ì¥¤¤ò¼«Æ°ÅªÃµÃΤ·¡¢ºÆ¹½ÃÛ¤·¤Þ¤¹

S.M.A.R.T¥¢¥ì¥¤¥â¥Ë¥¿¥ê¥ó¥°¤ò¥µ¥Ý¡¼¥È¤·¡¢¹â¤¤¿®ÍêÀ­¤òÄó¶¡

64-bit LBA Âбþ¡¢£²TB°Ê¾å¤Î¥Ç¥£¥¹¥¯¥¹¥Ú¡¼¥¹¤òÄó¶¡

¥Ö¥é¥¦¥¶¥Ù¡¼¥¹¤Ç¤Î´ÉÍý¥½¥Õ¥È¥¦¥§¥¢¤ËÂбþ

¥³¥Þ¥ó¥É¥é¥¤¥ó¥¤¥ó¥¿¡¼¥Õ¥§¡¼¥¹ (CLI)

¥¤¥Ù¥ó¥È¤È¥¨¥é¡¼¤òSMTP¤Ë¤è¤ê¼«Æ°Åª¤ËE¥á¡¼¥ë¤ÇÄÌÃÎ

¥½¥Õ¥È¥¦¥§¥¢(Web GUI, RAID GUI and CLI) ¤òÍøÍѤ·¤Æ¥ê¥â¡¼¥È´ÉÍý¤¬²Äǽ

¥µ¥Ý¡¼¥ÈOS¡§Windows (XP, 2000ޤServer 2003ޤx64ޤEditionޤVista)ޤ Linuxޤ FreeBSD µÚ¤Ó Mac OS XÂбþ

RoHSÂбþ

¥ì¥¤¥É´ÉÍý¥Ä¡¼¥ë
BIOS
Web based RAID
Management Software and CLI
¥µ¥Ý¡¼¥È¤µ¤ì¤ëOS
¥µ¥Ý¡¼¥ÈOS¡§Windows (XP, 2000ޤServer 2003ޤx64ޤEditionޤVista)ޤ Linuxޤ FreeBSD µÚ¤Ó Mac OS XÂбþ
Limited Warranty

 3 ǯ
 
| | |
Copyright © 2007 HighPoint Technologies, Inc